Home/Product ranges/Electrical cables
DEMAC rangeElectrical cable reels
Go to series for signals, power, vertical downward travel or motor drive. Each series page lets you check the cable, slip ring assembly and part numbers.


Choose according to cable and installation
Signals and multiple conductors

CR 025
Signal reel. Compare cable and conductors.
View part numbers
CR 10
Multi-conductor electrical series.
View part numbers
CR 15
1,5 mm² cable and 6 A; conductors and travel depend on the part number.
View part numbers
CR 25
2,5 mm² cable and 16 A; conductors and travel depend on the part number.
View part numbersPower and installation

700 series
Enclosed reel with cable stop.
View part numbers
6000 series
Compare electrical specifications by part number.
View part numbers
Horizontal LCR
Cable reel for horizontal installation.
View part numbers
LCR/VD
Version for vertical downward travel.
View part numbers
500 series
Compare power-supply configurations.
View part numbersMotorised or single-spiral spring-driven
Compare electrical specifications and travel
Voltage, current to transmit, conductor number and cross-section, usable length and mounting must be compatible within the same part number.
| Series | Voltage | Current | Conductors | Length |
|---|---|---|---|---|
| 50 V | 1 A | 2 to 4 | 2 to 3,3 m | |
| 50 V | 4 A | 2 to 36 | 5 to 40 m | |
| 50 V | 6 A | 2 to 36 | 5 to 42 m | |
| 50 V | 16 A | 3 to 18 | 6 to 40 m | |
| 12 to 400 V | — | 1 to 5 | 5 to 35 m | |
| 230 to 400 V | 30 to 150 A | 3 to 24 | 10 to 55 m | |
| 400 V | 2 to 176 A | 4 to 36 | 15 to 80 m | |
| 230 to 400 V | up to 450 A | 1 to 5 | 10 to 30 m | |
| Motorised | — | — | up to 36 | 50 to 100 m in the general catalogue; other travel distances subject to assessment |
The table ranges point to a series. The part number then defines the cable-length combination, bracket and permissible electrical conditions.
Checks before replacement
Permissible power: check wound or unwound state
Permissible power can differ according to how much cable remains on the drum. Use the part-number values and conditions specified by the manufacturer.
The 700 series publishes values for wound and unwound cable. The ratio varies by part number : it is not a factor applicable to the whole range.
For the quotation, state the electrical load and the length that will remain wound during operation.
Single-spiral or multi-spiral
With single-spiral winding, turns are arranged side by side. Compare the dimensions and electrical specifications of the CR 1200 with the installation constraints.
With multi-spiral winding, cable is stacked in layers. Check capacity for the actual cable diameter and the operating conditions for the part number.
The bracket depends on the conductor-length combination, not conductor count alone
Two brackets are available on the CR series. The S1 has hole centres of 55 by 80 mm, the S2 75 by 100 mm. Moving from one to the other does not follow a simple rule: on the CR 15, 16x1,5 at 34 m uses S2 while the same cable at 25 m uses S1. The bracket is specified for each part number, and determines the chassis drilling pattern.
Horizontal or vertical
A suspended cable carries its own weight over its entire length. The LCR/VD series is designed for this and is not simply an LCR with a reinforced spring: it is a more limited range.
Horizontal and vertical lengths cannot be transferred directly. With 4x10 mm², travel changes from 80 m horizontally to 40 vertically. A notable exception: 7x1,5 mm² reaches 80 m vertically compared with 45 horizontally.
The vertical cables specify a breaking load. This value must not be used as a permissible operating or pulling load: have the limits applicable to the cable and its mounting confirmed.
Signals, fieldbus and sensors
CR series accept CANbus, Ethernet and Profinet as options, subject to approval — the manufacturer does not automatically guarantee digital signal integrity through a slip ring assembly.
For a hybrid cable or an industrial network, specify the protocol, connection diagram and cable part number. The tables distinguish servomotor constructions, multi-conductor cables and CANbus or Profinet connections; their specifications are not interchangeable.
To measure length or angle rather than transmit current, see LR sensors, LR120 and LR195.
What to send for a quotation
- For a replacement: full part number, photograph of the nameplate and views of the existing installation.
- Voltage, actual current and number of conductors.
- Whether a neutral conductor is distributed.
- Travel length, and the amount of cable that will remain wound during operation.
- Horizontal application or vertical downward travel, including height.
- Bus protocol, where applicable.
- Achievable drilling centres.
- Water exposure: series range from IP 48 to IP 66.
Quotations and technical advice on request.