DEMAC range · Quotations and technical advice on request

HomeElectrical cable reelsLCR/VD cable reel — vertical downward travel, 400 V

LCR/VD cable reel — vertical downward travel, 400 V

LCR/VD for vertical downward travel: 400 V, IP 66. Cables and lengths depend on the part number; provide the full code and mounting drawing for your enquiry.

Conductors
12x · 18x · 24x
Cross-section
1.5 mm² · 10 mm² · 16 mm²
Voltage
400 V
Material
Painted steel

LCR/VD cable reel — vertical downward travel, 400 V | DEMAC

Technical specifications

Technical specifications

Product type

Electrical cable reel

Application

Electrical cable, Mobile machinery and cranes

Rewind mechanism

Automatic (spring rewind)

Material

Painted steel

Type de fixation

Flange mounting

Voltage

400 V

Current 21 A, 35 A, 88 A, 176 A
Number of conductors 4x, 5x, 7x, 12x, 18x, 24x, 36x
Cross-section

1.5 mm², 10 mm², 16 mm², 2.5 mm², 25 mm², 4 mm², 6 mm²

Length

15 m, 25 m, 30 m, 40 m, 45 m, 50 m, 80 m, 35 m, 38 m

Length range Up to 15 m, 15 to 30 m, 30 to 50 m, 50 to 100 m
ATEX zone

No

Maximum fluid temperature

60 °C

Equipment

With cable, Without cable

Type de câble

PUR-HF

Technical drawings View technical drawings

Key points

Spring-driven LCR/VD for vertical downward travel: 400 V, IP 66, 21 to 176 A at the slip ring assembly depending on part number. Lengths from 15 to 80 m depending on the cable.

Part number / replacement

Send the full code, suffixes and a nameplate photograph. For a new configuration: cable, required current, usable length, unwinding direction and installation drawing.

Options

The catalogue presents a version fitted with PUR-HF cable, or supplied without cable. Standard or /F bracket. CANbus, Ethernet and Profinet subject to approval.

Installation and operating conditions

  • Automatic spring return; the catalogue excludes manual use.
  • Maximum cable speed: 30 m/min. Temperature: -20 to +60 °C. Protection: IP 66.
  • LCRD: right-hand model; LCRS: left-hand model. The /VD suffix identifies the vertical application shown by the manufacturer.
  • Standard bracket: four Ø 11 mm holes, centre distances 100 × 40 mm; overall dimensions 120 × 60 mm on the drawing.
  • /F bracket: four Ø 17 mm holes on a Ø 170 mm pitch circle, Ø 200 mm flange. Check the drawing for the selected part number.

For your enquiry

  • Part number and quantity, if known; a nameplate photograph for a replacement.
  • Number of conductors, cross-section, voltage and operating current; presence of a neutral conductor and signal lines.
  • Usable length, downward travel and mounting heights, speed and machine movements.
  • Available mounting, exit direction, required cable and environmental constraints.

Vertical LCR/VD part numbers

All entries from pages 66–67 of the general catalogue are reproduced below. Usable length in metres; cable diameter and dimensions A to E in millimetres. Voltage: 400 V.

Cable Ø Length Slip ring assembly Part number A B C D E
4x1,5 mm² 11 45 3F+T 21 A LCRD 520.041545/VD 410 215 520 390 150
4x2,5 mm² 12 40 3F+T 35 A LCRD 520.042540/VD 410 215 520 390 150
4x4 mm² 13 35 3F+T 35 A LCRD 570.044035/VD 410 215 570 390 150
4x4 mm² 13 45 3F+T 35 A LCRD 570.044045/VD 410 215 570 390 150
4x6 mm² 15 30 3F+T 35 A LCRD 600.046030/VD 450 255 600 390 200
4x6 mm² 15 50 3F+T 35 A LCRD 700.046050/VD 450 255 700 390 200
4x10 mm² 19 40 3F+T 88 A LCRD 600.041040/VD 450 255 600 390 200
4x16 mm² 21 15 3F+T 88 A LCRD 600.041615/VD 450 215 600 390 200
4x16 mm² 21 38 3F+T 88 A LCRD 700.041638/VD 450 215 700 390 200
4x25 mm² 25 25 3F+T 176 A LCRD 600.042525/VD 450 255 700 390 200
5x1,5 mm² 12 50 3F+N+T 21 A LCRD 520.051550/VD 450 255 520 390 150
5x2,5 mm² 13 35 3F+N+T 35 A LCRD 520.052535/VD 450 255 520 390 150
5x2,5 mm² 13 50 3F+N+T 35 A LCRD 600.052550/VD 450 255 600 390 150
5x6 mm² 18 30 3F+N+T 35 A LCRD 600.056030/VD 490 255 600 390 200
5x6 mm² 18 35 3F+N+T 35 A LCRD 600.056035/VD 490 255 600 390 200
5x6 mm² 18 40 3F+N+T 35 A LCRD 700.056040/VD 490 255 700 390 200
5x10 mm² 20 35 3F+N+T 88 A LCRD 700.051035/VD 415 255 700 390 200
5x16 mm² 23 25 3F+N+T 88 A LCRD 700.051625/VD 415 255 700 390 200
7x1,5 mm² 11 45 21 A LCRD 500.071545/VD 410 215 500 390 150
7x1,5 mm² 11 80 21 A LCRD 700.071580/VD 410 256 700 490 150
7x2,5 mm² 14 35 35 A LCRD 570.072535/VD 410 215 570 390 150
12x1,5 mm² 16 50 21 A LCRD 700.121050/VD 445 255 700 390 200
12x2,5 mm² 20 35 35 A LCRD 570.122535/VD 490 256 570 390 200
18x1,5 mm² 18 40 21 A LCRD 700.161040/VD 490 255 700 490 150
24x2,5 mm² 23 25 35 A LCRD 700.242525/VD 430 255 700 490 200
36x2,5 mm² 29 15 35 A LCRD 650.362515/VD 430 215 650 390 200

The stated current is that of the slip ring assembly; it is not sufficient to establish the cable’s current-carrying capacity under actual operating conditions. Lengths apply only to their associated configurations in the table.

Code details to confirm

The 4x25 mm², 25 m entry bears code LCRD 600.042525/VD with dimension C of 700 mm. The 12x1,5 and 18x1,5 codes cannot be decoded literally from the conductor count and cross-section. These details are retained as published; have the part number and drawing confirmed before ordering.

Unsure about the part number?

Tell us the voltage, current, number of conductors and cross-section, payout length and working environment.

Request a quote

Product:

Enter your part number, quantity or required specifications. Fields marked * are required.

Enquiry type *
Your requirements *
If you know the part number, provide the full code and quantity. For a replacement, send the reel's serial number, which is needed to identify the unit to be replaced. It is shown on the identification label; if this is unavailable, see the illustrated locations on the Contact page. For a new configuration, specify the number of hoses or cables, usable length and available technical data. Tell us what you know; we will help you complete the details.
Company
Name
Email address *
Telephone
Attach a file
Maximum file size: 10 MB
For a replacement: a clear photo of the label showing the serial number, plus a view of the reel or its installation. If the label is unavailable, see the illustrated locations on the Contact page. You may also attach a drawing or part number. Up to 3 files, maximum 10 MB per file.

Open the form on the Contact page

Nous appeler