DEMAC range · Quotations and technical advice on request

Home›Hoses and cables›Vertical PUR-HF cables and hybrid cables

Vertical PUR-HF cables and hybrid cables

PUR-HF cables for vertical mounting and H1 to H8 hybrids. Part numbers, compositions and signal data, with breaking loads where stated.

Conductors
10x · 12x · 18x
Cross-section
0.5 mm² · 1 mm² · 1.5 mm²
Vertical PUR-HF cables and hybrid cables | DEMAC

Technical specifications

Technical specifications

Product type

Cable

Application

Electrical cable

Cable type

Hybrid bus cable, PUR-HF

Number of conductors 4x, 5x, 7x, 10x, 12x, 18x, 24x, 36x
Cross-section

0.5 mm², 35 mm², 1 mm², 1.5 mm², 10 mm², 16 mm², 2.5 mm², 25 mm², 4 mm², 6 mm²

Maximum fluid temperature 80 °C, 90 °C
ATEX zone

No

DEMAC cable-family illustration. Construction, materials and conductor sizes depend on the selected reference.

The section CABLE-2 distinguishes PUR-HF cables for vertical applications from H1 to H8 hybrid cables. The codes and specifications in these two tables are not interchangeable.

To identify the cable

  • Cable code and marking, reel part number and photographs of the ends.
  • Conductors, cross-sections, signal or protocol and yellow-green conductor.
  • Length, mounting height, temperature and documented tensile constraints.

PUR-HF cables for vertical applications

The part numbers in this table are specified with a PUR sheath, textile reinforcement, a yellow-green conductor, a temperature range of −40 to +90 °C and voltage U0/U of 600/1000 V. External Ø in mm and mass in kg/m.

Vertical cables — stated breaking load in N
Conductors Type Code Ø Mass Breaking load
4 4x1.5 810.03.56 11.2 0.150 1 800 N
4x2.5 810.02.75 12.2 0.200 1 200 N
4x4 810.02.91 13.5 0.280 2 000 N
4x6 810.00.54 15.2 0.370 2 000 N
4x10 810.02.95 18.6 0.600 2 500 N
4x16 810.03.18 21.4 0.850 2 800 N
4x25 810.03.34 24.9 1.230 3 600 N
4x35 810.03.24 30.2 1.760 4 300 N
5 5x1.5 810.03.38 11.7 0.170 2 800 N
5x2.5 810.03.62 13.0 0.220 2 800 N
5x4 810.03.54 14.5 0.330 3 600 N
5x6 810.02.76 17.6 0.480 4 300 N
5x10 810.03.35 19.9 0.720 3 600 N
5x16 810.03.36 23.0 1.030 —
7 7x1.5 810.03.23 13.2 0.220 3 600 N
7x2.5 810.02.47 14.7 0.310 3 600 N
12 12x1.5 810.02.72 16.7 0.360 3 600 N
12x2.5 810.01.51 20.1 0.550 4 300 N
18 18x1.5 810.02.99 18.1 0.470 3 600 N
18x2.5 810.01.80 20.4 0.670 4 300 N
24 24x1.5 810.00.41 20.2 0.600 3 600 N
24x2.5 810.00.45 22.9 0.870 4 300 N
36 36x2.5 810.03.26 29.0 1.400 —

Breaking load is not a permissible working load. The missing values for 810.03.36 and 810.03.26 must be requested. Part number 810.02.75 is indeed stated as 1 200 N in the source.

H1 to H8 hybrid cables

Hybrid cables — part numbers and composition; PUR sheath
Type Code Composition (cross-sections in mm² except AWG) Ø mm Mass kg/m Yellow-green Reinforcement Temperature °C U0/U V
H1 810.01.94 (4x1.5) + 2×(2x0.75) 12.3 0.209 Yes Textile −40/+90 600/1000
H2 810.01.19 (9x1.5) + (1x2x0.22) Sc 12 — No Kevlar −40/+80 —
H3 810.01.58 (14x1.5) + (1x2x0.22) Sc 16 — No Kevlar −40/+80 —
H4 810.00.30 (4x2.5) + (16x1) + (4x1) 18.2 0.509 Yes (2.5 mm²) Kevlar −40/+80 —
H5 810.02.66 (12x0.5) + (1x2x0.22) Sc 9.5 — No Kevlar −40/+80 —
H6 810.02.96 (10x1) + (16x0.5) + (2x0.22) Sc 16 — No Kevlar −40/+80 —
H7 810.02.59 (10x1.5) + (2x2×AWG26) 14.5 0.325 No Kevlar −40/+80 —
H8 810.02.85 (7x0.5) + (2x1.5) + (2x2x0.22) 18.5 — No Kevlar −40/+80 —
Published signal specifications for hybrids
Type Stated signal Contacts Impedance Ω Speed Mbit/s
H1 Servomotors 4 — —
H2 CANBus 2 120 1
H3 CANBus 2 120 1
H4 Multicore — — —
H5 CANBus 2 120 1
H6 CANBus 2 120 1
H7 Profinet Cat 5e 4 100 100
H8 CANBus 4 120 1

For vertical downward travel on a reel, see the data sheet LCR/VD. Validation concerns the combination of cable, slip ring assembly, length and installation, not only the protocol listed in the table.

Unsure about the part number?

Tell us the voltage, number of conductors, cross-section and required length.

Request a quote

Product:

Enter your part number, quantity or required specifications. Fields marked * are required.

Enquiry type *
Your requirements *
If you know the part number, provide the full code and quantity. For a replacement, send the information available: serial number, a clear photo of the nameplate, and a view of the reel and its installation. The serial number is required for certain identification; if it cannot be found, submit your enquiry anyway and see the illustrated locations on the Contact page. For a new configuration, specify the number of hoses or cables, usable length and available technical data. Tell us what you know; we will help you complete the details.
Company
Name
Email address *
Telephone
Attach a file
Maximum file size: 10 MB
For a replacement, if possible attach a clear photo of the label showing the serial number, plus a view of the reel or its installation. If the number cannot be found, send the photos, drawing or part number available; your enquiry can be assessed and completed afterwards. Up to 3 files, maximum 10 MB per file.

Open the form on the Contact page

Call us