DEMAC range · Quotations and technical advice on request

HomeElectrical cable reels6000 series cable reel — 400 V

6000 series cable reel — 400 V

DEMAC 6000 series: spring return, 230 or 400 V, 3 to 24 conductors depending on the part number. Selection tables for standard and vertical downward travel versions.

Conductors
12x · 24x · 3x
Cross-section
1.5 mm² · 10 mm² · 16 mm²
Voltage
230 V · 400 V
Material
Painted steel

6000 series cable reel — 400 V | DEMAC

Technical specifications

Technical specifications

Product type

Electrical cable reel

Voltage 230 V, 400 V
Current 30 A, 50 A, 100 A, 150 A
Application

Electrical cable, Mobile machinery and cranes

Rewind mechanism

Automatic (spring rewind)

Material

Painted steel

Number of conductors 3x, 4x, 5x, 7x, 12x, 24x
Cross-section

1.5 mm², 10 mm², 16 mm², 2.5 mm², 25 mm², 4 mm², 6 mm²

Length range Up to 15 m, 15 to 30 m, 30 to 50 m, 50 to 100 m
ATEX zone

No

Maximum fluid temperature

60 °C

Equipment

With cable, Without cable

KW

1.2 kW, 1.6 kW, 11 kW, 13 kW, 15 kW, 17 kW, 22 kW, 25 kW, 3 kW, 3.5 kW, 31 kW, 32 kW, 4 kW, 40 kW, 5 kW, 50 kW, 6 kW, 7 kW, 8 kW, 9 kW

Technical drawings View technical drawings

The DEMAC 6000 series is a spring-driven cable reel, rated at 230 or 400 V depending on the cable. To identify a part number, compare the usable length, slip ring assembly and operating position.

Key features

  • 3, 4, 5, 7, 12 or 24 conductors depending on the part number.
  • 30, 50, 100 or 150 A slip ring assemblies; power ratings are listed separately below.
  • IP 66; maximum speed 30 m/min; -20 to +60 °C.

Part number / replacement

Provide the full code and quantity, with a photo of the nameplate if possible. Specify standard or vertical downward travel, the cable, usable length and mounting dimensions to be retained.

Options

CANBus, Ethernet and Profinet subject to approval. Technical drawings available on request. Automatic spring return: the catalogue excludes manual operation.

Dimensions and installation to be confirmed

  • Dimensions on request: 4x2,5 mm² in 45 m; 5x1,5 mm² in 40 and 50 m; 5x2,5 mm² in 55 m; 5x6 mm² in 30 m; 7x2,5 mm² in 35 and 40 m.
  • Some dimensions are also missing from other rows: request the complete drawing before replacement.
  • S1 and S2 brackets are shown depending on the part number; do not infer mounting centres from cable length alone.

Include with your enquiry

  • Part number or nameplate photo, and quantity.
  • Voltage, operating current, number of conductors and cross-section.
  • Usable length, outlet direction and mounting position.
  • Existing overall dimensions and mounting; any signal or data requirements.

Part numbers with cable: 3 and 4 conductors

Selection table covering all cable rows on pages 62–63: diameter, length, voltage, slip ring assembly, power and part numbers. Dimensions A to E, brackets and installation drawings must be checked against the drawing for the selected part number.

The two power values apply to the cable wound and unwound; they are neither a range nor values to multiply by the number of conductors. The rated current of the slip ring assembly alone does not establish the permissible cable current.

Cable (mm²) Cable Ø (mm) Usable length (m) Voltage (V) Slip ring assembly kW wound kW unwound Standard code with cable Vertical downward travel code with cable
3x1,5 8 15 230 2F+T 30 A 1,2 3,5 6002R 6002R
3x1,5 8 25 230 2F+T 30 A 1,2 3,5 6003R 6003R
3x1,5 8 30 230 2F+T 30 A 1,2 3,5 6004R 6005R
3x2,5 10 15 230 2F+T 30 A 1,6 5 6010R 6010R
3x2,5 10 20 230 2F+T 30 A 1,6 5 6011R 6011R
3x2,5 10 30 230 2F+T 30 A 1,6 5 6012R 6013R
4x1,5 9 10 400 3F+T 30 A 4 6 6020R 6020R
4x1,5 9 15 400 3F+T 30 A 4 6 6021R 6021R
4x1,5 9 20 400 3F+T 30 A 4 6 6022R 6022R
4x1,5 9 25 400 3F+T 30 A 3 5 6023R 6024R
4x1,5 9 30 400 3F+T 30 A 3 5 6025R 6026R
4x1,5 9 35 400 3F+T 30 A 3 5 6027R 6028R
4x2,5 11 10 400 3F+T 30 A 7 9 6035R 6035R
4x2,5 11 15 400 3F+T 30 A 7 9 6036R 6036R
4x2,5 11 20 400 3F+T 30 A 7 9 6037R 6037R
4x2,5 11 25 400 3F+T 30 A 6 8 6038R 6039R
4x2,5 11 30 400 3F+T 30 A 6 8 6040R 6041R
4x2,5 11 40 400 3F+T 30 A 6 8 6042R
4x2,5 11 45 400 3F+T 30 A 6 8 6043R
4x4 15 12 400 3F+T 30 A 11 15 6050R 6050R
4x4 15 16 400 3F+T 30 A 11 15 6051R 6052R
4x4 15 20 400 3F+T 30 A 9 13 6053R 6054R
4x4 15 25 400 3F+T 30 A 9 13 6055R 6056R
4x4 15 30 400 3F+T 30 A 9 13 6057R 6058R
4x6 15 10 400 3F+T 30 A 17 22 6061R 6061R
4x6 15 15 400 3F+T 30 A 17 22 6062R 6063R
4x6 15 20 400 3F+T 30 A 17 22 6064R 6065R
4x6 15 27 400 3F+T 30 A 17 22 6066R 6067R
4x6 15 40 400 3F+T 30 A 17 22 6068R
4x10 23 13 400 3F+T 50 A 25 31 6075R 6075R
4x10 23 20 400 3F+T 50 A 25 31 6076R 6077R
4x10 23 25 400 3F+T 50 A 25 31 6078R 6079R
4x10 23 30 400 3F+T 50 A 25 31 6080R
4x16 24 10 400 3F+T 100 A 32 40 6085R 6086R
4x16 24 14 400 3F+T 100 A 32 40 6087R 6088R
4x16 24 20 400 3F+T 100 A 32 40 6089R 6090R
4x25 26 15 400 3F+T 150 A 40 50 6095R 6096R
4x25 26 20 400 3F+T 150 A 40 50 6097R 6098R

Part numbers with cable: 5 to 24 conductors

Cable (mm²) Cable Ø (mm) Usable length (m) Voltage (V) Slip ring assembly kW wound kW unwound Standard code with cable Vertical downward travel code with cable
5x1,5 10 15 400 3F+N+T 30 A 1,2 3,5 6105R 6105R
5x1,5 10 25 400 3F+N+T 30 A Not stated Not stated 6106R 6107R
5x1,5 10 30 400 3F+N+T 30 A Not stated Not stated 6108R 6109R
5x1,5 10 40 400 3F+N+T 30 A Not stated Not stated 6110R
5x1,5 10 50 400 3F+N+T 30 A Not stated Not stated 6112R
5x2,5 10 10 400 3F+N+T 30 A 7 9 6114R 6114R
5x2,5 10 15 400 3F+N+T 30 A 7 9 6115R 6115R
5x2,5 10 20 400 3F+N+T 30 A 7 9 6116R 6117R
5x2,5 10 30 400 3F+N+T 30 A 6 8 6118R 6119R
5x2,5 10 55 400 3F+N+T 30 A 6 8 6118R.55
5x4 16 10 400 3F+N+T 30 A 11 15 6120R 6121R
5x4 16 20 400 3F+N+T 30 A 11 15 6122R 6123R
5x4 16 30 400 3F+N+T 30 A 9 13 6124R
5x6 19 10 400 3F+N+T 30 A 17 22 6186R
5x6 19 20 400 3F+N+T 30 A 17 22 Not specified
5x6 19 30 400 3F+N+T 30 A 17 22 Not specified
7x2,5 14 10 400 30 A 7 9 6125R 6125R
7x2,5 14 20 400 30 A 7 9 6126R 6127R
7x2,5 14 25 400 30 A 6 8 6128R 6129R
7x2,5 14 30 400 30 A 6 8 6130R 6131R
7x2,5 14 35 400 30 A 6 8 6132R 6133R
7x2,5 14 40 400 30 A 6 8 6134R 6135R
12x1,5 15 10 400 30 A 1,2 3,5 6140R 6140R
12x1,5 15 20 400 30 A 1,2 3,5 6141R 6142R
12x1,5 15 30 400 30 A 1,2 3,5 6143R 6144R
12x2,5 15 10 400 30 A 7 9 6145R 6146R
12x2,5 15 15 400 30 A 7 9 6147R 6148R
24x1,5 21 14 400 30 A 1,2 3,5 6170R 6171R
24x1,5 21 20 400 30 A 1,2 3,5 6172R 6173R
24x1,5 21 35 400 30 A 1,2 3,5 6174R
24x1,5 21 40 400 30 A 1,2 3,5 6175R
24x2,5 23 15 400 30 A 6 8 6180R 6181R
24x2,5 23 20 400 30 A 6 8 6182R 6183R
24x2,5 23 25 400 30 A 6 8 6184R 6185R

For 5x1,5 mm², the power rating is specified only in the 15 m row; the cells for the other lengths are blank in the catalogue and are not extrapolated here.

The dash reflects a missing part number in the relevant catalogue column; it does not mean that a standard version is suitable for vertical downward travel. For 5x6 mm² in 20 and 30 m, no code is given: the execution must be specified.

Manual specific to model 6036R

The 6036R manual, edition 12/2025, specifies for this execution a 4x2,5 mm² cable of 15 m, a limit of 400 V/16 A, IP 66 and -20 to +80 °C. These data must not be extended to other part numbers in the series.

The catalogue lists the slip ring assembly current and wound/unwound power ratings separately. For replacement, the nameplate and manual for the model concerned still need to be checked. Do not infer the permissible current of the assembly from the slip ring assembly rating alone.

Installation and maintenance must be carried out by qualified personnel, following the manual for the execution concerned. Spring prewinding settings must not be transferred from one part number to another.

Related products

Unsure about the part number?

Tell us the voltage, current, number of conductors and cross-section, payout length and working environment.

Request a quote

Product:

Enter your part number, quantity or required specifications. Fields marked * are required.

Enquiry type *
Your requirements *
If you know the part number, provide the full code and quantity. For a replacement, send the reel's serial number, which is needed to identify the unit to be replaced. It is shown on the identification label; if this is unavailable, see the illustrated locations on the Contact page. For a new configuration, specify the number of hoses or cables, usable length and available technical data. Tell us what you know; we will help you complete the details.
Company
Name
Email address *
Telephone
Attach a file
Maximum file size: 10 MB
For a replacement: a clear photo of the label showing the serial number, plus a view of the reel or its installation. If the label is unavailable, see the illustrated locations on the Contact page. You may also attach a drawing or part number. Up to 3 files, maximum 10 MB per file.

Open the form on the Contact page

Nous appeler